Processing. Please wait. Brand: Mitsubishi Save Listing| Email Listing | Share Product Name: Mitsubishi MUZHM18NAU2 MSZHM18NAU1 18000 BTU SEER 18 Mini Split HEAT PUMP Item#: MUZHM18NAU2 MSZHM18NAU1 Reg Price: $4,760.00 Your Price: $2,480.00 Accessories: Whats This? 15 ft of copper lineset - install kit - insulated with flared fittings. If you need longer lengths, please call us to upgrade your order. $150.01 Opt Out Total Price : $2,630.01 Choose QTY: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Required Product Details Manuals Video Warranty Shipping Info Returns / Policy Ask A Question Product Details - MUZHM18NAU2 MSZHM18NAU1 Product Specficiations Mitsubishi MUZHE18NA MSZHE18NA Wall Mounted Single HEAT PUMP Mini Split 18 SEER - 18,000BTU The Mitsubishi MSZ-HE Mini Split Heat Pump System provides individual comfort control. The air handlers are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling and heating performance at low sound levels. Standard Features: Wall mounted indoor unit Single connection only Auto fan speed control: Low, Medium, High, and Super High Hand held Wireless Remote Controller Residential Applications: Sun rooms Wine cellars Guest quarters Garage workshops Homes without duct work Bedrooms and family rooms Room additions and renovations Commercial Applications: Storage facilities Hotels and other lodging Computer rooms/server rooms Offices in warehouse spaces Restaurant kitchen and prep areas Buildings where security concerns prevent the use of window units Internal areas without exterior wall access applications Commercial add on jobs where the existing air conditioning system cannot be stretched. Historical renovations or any application where preserving the look of the original structure is essential. SPECIFICATIONS Cooling*1 Rated Capacity..............................................................17,200 Btu/h Maximum Capacity...........................................................18,000 Btu/h SEER.............................................................................18.0 Btu/h/W Total Input.........................................................1,640 (240-2,070) W Heating at 47° F*2 Rated Capacity..............................................................18,000 Btu/h Maximum Capacity...........................................................20,900 Btu/h HSPF...............................................................................8.5 Btu/h/W Total Input.........................................................1,900 (230-2,680) W Heating at 17° F*3 Rated Capacity..............................................................13,400 Btu/h Rated Total Input..................................................................1,450 W Maximum Capacity........................................................17,200 Btu/h Heating at 5° F*4 Maximum Capacity........................................................13,562 Btu/h Electrical Requirements Power Supply.........................................208 / 230V, 1-Phase, 60 Hz Breaker Size...............................................................................15 A Voltage Indoor - Outdoor S1-S2.............................................AC 208 / 230 V Indoor - Outdoor S2-S3......................................................DC ±24 V Indoor - Remote Controller.................................................DC ±24 V Indoor Unit MCA............................................................................................ 1.0 A Blower Motor (ECM) ..........................................................0.76 F.L.A. Airflow (Lo - Med - Hi - Super Hi) Cooling............................................... 275-339-420-533 Dry CFM 240-304-385-498 Wet CFM Heating............................................... 275-339-431-512 Dry CFM Sound Pressure Level (Lo - Med - Hi - Super Hi) Cooling ............................................................ 33-38-44-49 dB(A) Heating ............................................................ 33-38-43-48 dB(A) External Finish Color ......................................... Munsell 1.0Y 9.2/0.2 Dimension Unit Inches:..........................................11-5/8 H x 31-7/16 W x 9-1/8 D mm: ..........................................................295 H x 798 W x 232 D Weight Unit ....................................................................22 lbs. / 10kg Field Drainpipe Size O.D. ......................................... 5/8” x 15.88 mm Outdoor Unit MCA............................................................................................. 14 A MOCP.......................................................................................... 15 A Fan Motor (ECM) ...............................................................0.93 F.L.A. Compressor.......................................DC Inverter-driven Twin Rotary Sound Pressure Level Cooling *1........................................................................54 dB(A) Heating *2 .......................................................................56 dB(A) External Finish Color ............................................ Munsell 3Y 7.8/1.1 External Dimensions Inches:............................................33-1/16 H x 33-7/16 W x 13 D mm: ..........................................................840 H x 849 W x 330 D Weight ........................................................................119 lbs. / 54 kg Refrigerant Type ...................................................................... R410A Refrigerant Pipe Gas Side O.D. ........................................................1/2” / 12.7 mm Liquid Side O.D. .....................................................1/4” / 6.35 mm Refrigerant Pipe Length Height Difference (Max.) ............................................... 50’ / 15 m Length (Max.) .............................................................. 100’ / 30 m Connection Method Indoor/Outdoor ....................................................................Flared • Click here for MITSUBISHI'S LIMITED WARRANTY STATEMENT Your Phone Number : Enter Your Phone Number Your Email : Enter Your Email Not valid email address What is your message about : - Select One - Sales Questions General Support Technical Support Webmaster Please select your message about What Is The Status Of Your Project? : - Select One - Ready To Buy Planning/Budgeting Just Curious/Not Buying Anytime Soon Please select status of your project Type your name and message here : Verification Code : 8 + 4 Send Shop for Mitsubishi and browse manuals and details of MUZHM18NAU2 MSZHM18NAU1 AC Repair Bartlett, IL HVAC Service El Cajon, CA Furnace Repair Vacaville, CA HVAC Service Sayreville, NJ Duct Cleaning Riverside, CA Commercial Electrician Palm Coast, FL Top Watch This Item Your Phone Number: Your Email: Message here: Make an offer Quantity you would like to buy: 1 2 3 4 5 6 7 8 9 10 How much would you like to pay for each unit: Type your Message: Shipping Address: URL of the website where you saw cheaper price Or better deal: Your email address: Your phone number: E-mail a friend about this item Your friend email: Your Email: Message here: Email For Price Your Phone Number: Your Email: Shipping Zip Code: How soon do you need this product?: Immidiately Within a week Within couple of months Just looking for price Message here:
Brand: Mitsubishi Save Listing| Email Listing | Share Product Name: Mitsubishi MUZHM18NAU2 MSZHM18NAU1 18000 BTU SEER 18 Mini Split HEAT PUMP Item#: MUZHM18NAU2 MSZHM18NAU1 Reg Price: $4,760.00 Your Price: $2,480.00 Accessories: Whats This? 15 ft of copper lineset - install kit - insulated with flared fittings. If you need longer lengths, please call us to upgrade your order. $150.01 Opt Out Total Price : $2,630.01 Choose QTY: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Required
Product Details Manuals Video Warranty Shipping Info Returns / Policy Ask A Question Product Details - MUZHM18NAU2 MSZHM18NAU1 Product Specficiations Mitsubishi MUZHE18NA MSZHE18NA Wall Mounted Single HEAT PUMP Mini Split 18 SEER - 18,000BTU The Mitsubishi MSZ-HE Mini Split Heat Pump System provides individual comfort control. The air handlers are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling and heating performance at low sound levels. Standard Features: Wall mounted indoor unit Single connection only Auto fan speed control: Low, Medium, High, and Super High Hand held Wireless Remote Controller Residential Applications: Sun rooms Wine cellars Guest quarters Garage workshops Homes without duct work Bedrooms and family rooms Room additions and renovations Commercial Applications: Storage facilities Hotels and other lodging Computer rooms/server rooms Offices in warehouse spaces Restaurant kitchen and prep areas Buildings where security concerns prevent the use of window units Internal areas without exterior wall access applications Commercial add on jobs where the existing air conditioning system cannot be stretched. Historical renovations or any application where preserving the look of the original structure is essential. SPECIFICATIONS Cooling*1 Rated Capacity..............................................................17,200 Btu/h Maximum Capacity...........................................................18,000 Btu/h SEER.............................................................................18.0 Btu/h/W Total Input.........................................................1,640 (240-2,070) W Heating at 47° F*2 Rated Capacity..............................................................18,000 Btu/h Maximum Capacity...........................................................20,900 Btu/h HSPF...............................................................................8.5 Btu/h/W Total Input.........................................................1,900 (230-2,680) W Heating at 17° F*3 Rated Capacity..............................................................13,400 Btu/h Rated Total Input..................................................................1,450 W Maximum Capacity........................................................17,200 Btu/h Heating at 5° F*4 Maximum Capacity........................................................13,562 Btu/h Electrical Requirements Power Supply.........................................208 / 230V, 1-Phase, 60 Hz Breaker Size...............................................................................15 A Voltage Indoor - Outdoor S1-S2.............................................AC 208 / 230 V Indoor - Outdoor S2-S3......................................................DC ±24 V Indoor - Remote Controller.................................................DC ±24 V Indoor Unit MCA............................................................................................ 1.0 A Blower Motor (ECM) ..........................................................0.76 F.L.A. Airflow (Lo - Med - Hi - Super Hi) Cooling............................................... 275-339-420-533 Dry CFM 240-304-385-498 Wet CFM Heating............................................... 275-339-431-512 Dry CFM Sound Pressure Level (Lo - Med - Hi - Super Hi) Cooling ............................................................ 33-38-44-49 dB(A) Heating ............................................................ 33-38-43-48 dB(A) External Finish Color ......................................... Munsell 1.0Y 9.2/0.2 Dimension Unit Inches:..........................................11-5/8 H x 31-7/16 W x 9-1/8 D mm: ..........................................................295 H x 798 W x 232 D Weight Unit ....................................................................22 lbs. / 10kg Field Drainpipe Size O.D. ......................................... 5/8” x 15.88 mm Outdoor Unit MCA............................................................................................. 14 A MOCP.......................................................................................... 15 A Fan Motor (ECM) ...............................................................0.93 F.L.A. Compressor.......................................DC Inverter-driven Twin Rotary Sound Pressure Level Cooling *1........................................................................54 dB(A) Heating *2 .......................................................................56 dB(A) External Finish Color ............................................ Munsell 3Y 7.8/1.1 External Dimensions Inches:............................................33-1/16 H x 33-7/16 W x 13 D mm: ..........................................................840 H x 849 W x 330 D Weight ........................................................................119 lbs. / 54 kg Refrigerant Type ...................................................................... R410A Refrigerant Pipe Gas Side O.D. ........................................................1/2” / 12.7 mm Liquid Side O.D. .....................................................1/4” / 6.35 mm Refrigerant Pipe Length Height Difference (Max.) ............................................... 50’ / 15 m Length (Max.) .............................................................. 100’ / 30 m Connection Method Indoor/Outdoor ....................................................................Flared • Click here for MITSUBISHI'S LIMITED WARRANTY STATEMENT Your Phone Number : Enter Your Phone Number Your Email : Enter Your Email Not valid email address What is your message about : - Select One - Sales Questions General Support Technical Support Webmaster Please select your message about What Is The Status Of Your Project? : - Select One - Ready To Buy Planning/Budgeting Just Curious/Not Buying Anytime Soon Please select status of your project Type your name and message here : Verification Code : 8 + 4 Send Shop for Mitsubishi and browse manuals and details of MUZHM18NAU2 MSZHM18NAU1 AC Repair Bartlett, IL HVAC Service El Cajon, CA Furnace Repair Vacaville, CA HVAC Service Sayreville, NJ Duct Cleaning Riverside, CA Commercial Electrician Palm Coast, FL Top